Obtain parasternal long and short axis, apical four-chamber and subcostal views. Grade LV function visually (normal, mildly, severely reduced, hyperdynamic) and look for pericardial effusion, gross valve failure and LV size.
At the bedside
Timed steps- 1
Phased-array probe
Set upCardiac preset; marker convention (screen marker on the right in cardiac mode). Patient supine or left lateral.
- 2
Parasternal long axis
View 13rd-4th left intercostal space, marker to right shoulder. LV size and function, mitral and aortic valves, pericardial vs pleural effusion (descending aorta).
- 3
Parasternal short axis
View 2Rotate 90° clockwise. 'Donut' LV at papillary level: regional wall motion, septal shape (D-sign in RV overload).
- 4
Apical four-chamber
View 3Apex beat, marker to left. RV:LV size ratio, global function, MAPSE/TAPSE, effusion.
- 5
Subcostal
View 4Below xiphoid, marker to left, probe flat. Best view in ventilated patients; effusion and RA/RV collapse; then rotate for IVC.
- 6
LV function
InterpretVisual EF: hyperdynamic (cavity obliteration), normal, reduced, severely reduced. E-point septal separation > 7 mm suggests reduced EF.
- 7
Tamponade
InterpretEffusion with RA systolic collapse, RV diastolic collapse, plethoric IVC; clinical diagnosis with haemodynamic compromise.
Five-view focused cardiac scan
| View | Probe position | Key questions |
|---|---|---|
| PLAX | Left parasternal, 3rd-4th ICS, marker to right shoulder | LV function, effusion, aortic root, MV/AV |
| PSAX | Same site, rotate 90° clockwise | Regional wall motion, D-sign |
| A4C | Apex, marker to patient's left | RV:LV ratio, TAPSE, global function |
| Subcostal 4C | Subxiphoid, flat probe | Effusion, tamponade, global function |
| Subcostal IVC | Rotate to long axis, marker cephalad | IVC size and variation |
References
- 1
- 2
Focused cardiac scan sequence
Step 1 of ~3
Decision: Pericardial effusion with chamber collapse?
Based on Via G, Hussain A, Wells M, et al; Perera P, Mailhot T, Riley D, Mandavia D. Educational use; follow local protocol.
Evidence
- International FoCUS recommendations 2014: focused cardiac ultrasound is accurate in trained hands for LV dysfunction, RV enlargement, pericardial effusion/tamponade and volume status assessment; it complements but does not replace comprehensive echo.
🇮🇳 India notes
- Portable ultrasound machines are widely available in Indian ICUs; ISCCM and other bodies run POCUS courses. Save images for review and quality assurance.
References
- 1
- 2
Test yourself
Module quiz · score 70% to complete the module